Industry

Power & Boilers

Shivam Engineering & Fabrication manufactures high-performance Forced Draught (FD), Induced Draught (ID) and combustion air blowers for thermal power plants, boilers, and captive power generation units.

Custom Tailor Made

We design and manufacture FD Fans, ID Fans, PA Fans and high-pressure blowers with precise specifications for boiler combustion, flue gas handling and power plant efficiency requirements.

Contact Us for More Information
Power & Boilers Application

Need FD, ID or PA Fans for Your Power Plant?

High-efficiency, heavy-duty blowers engineered for reliable performance in thermal power and boiler applications.

Storage Tank for Power Plants & Boilers

Heavy-duty, high-quality storage tanks engineered specifically for thermal power plants and industrial boilers – fuel oil, DM water, condensate, and chemical storage.

When power plant operators and boiler manufacturers across India need reliable, durable storage solutions for their critical fluids, they turn to Shivam Engineering & Fabrication. As a leading storage tank manufacturer for power plants and industrial boilers, we have supplied hundreds of units to thermal power plants, captive power plants, and industrial boiler houses across the country. Our storage tanks are engineered for safety, durability, and compliance with international standards – perfectly suited for the demanding requirements of power generation.

Why Power Plants Need Heavy-Duty Storage Tanks

Power plants and industrial boilers require large-volume storage of various liquids under demanding conditions. Our specially designed storage tanks feature:

  • Heavy-Duty Construction – Designed for continuous service and seismic zones.
  • Corrosion Protection – Epoxy coating, SS304, or SS316 based on service.
  • Leak-Proof Design – Double welding with full penetration and inspection.
  • Heating Systems – Steam coils or electric heaters for fuel oil tanks.
  • Insulation – For temperature maintenance and freeze protection.
  • Secondary Containment – Bund walls or double-wall construction.
  • Compliance – API 650, IS 2825, OISD, and statutory regulations.

Storage Tank Types for Power Plants & Boilers

Tank TypeConfigurationApplicationKey Features
Fuel Oil Storage TankVertical / HorizontalHFO, LDO, LSHS, dieselHeating coils, insulation, bund wall
DM Water Storage TankVertical cylindricalDe-mineralized waterSS304, pickled & passivated, nitrogen blanketing
Condensate Storage TankVertical cylindricalCondensate returnSS304 / MS with coating
Chemical Dosing TankVertical small capacityWater treatment chemicalsSS316, agitator option
Additive Storage TankVertical / SiloLimestone, ammonia, ureaMS / SS304, dust collection
Service Water TankVertical / Ground levelCooling water, service waterMS with epoxy coating, large capacity

Key Applications in Power Plants

1. Fuel Oil Storage Tanks

Storage of Heavy Fuel Oil (HFO), Light Diesel Oil (LDO), Low Sulphur Heavy Stock (LSHS), and start-up diesel for boiler burners. Features include steam heating coils, insulation, level indication, and secondary containment bunds as per OISD standards.

2. DM (De-mineralized) Water Storage Tanks

Storage of high-purity de-mineralized water for boiler feed. Manufactured in SS304 with pickled and passivated finish to prevent contamination. Features include nitrogen blanketing to prevent CO2 absorption and high-polish internal finish.

3. Condensate Storage Tanks

Storage of condensate returned from the steam system before polishing and reuse. Available in SS304 or epoxy-coated MS construction.

4. Chemical Dosing Tanks

Storage of water treatment chemicals (antiscalants, coagulants, biocides, oxygen scavengers, pH adjusters). Manufactured in SS316 with optional agitators for mixing.

5. Additive Storage Tanks (FGD / SCR)

Storage of limestone slurry for Flue Gas Desulfurization (FGD) and ammonia/urea for Selective Catalytic Reduction (SCR). Available as tanks or silos with dust collection systems.

6. Service Water Tanks

Large capacity storage for cooling water, fire protection water, and general service water.

Material Selection for Power Plant Applications

ApplicationRecommended MaterialCorrosion ProtectionDesign Standard
Fuel Oil (HFO/LDO)MSEpoxy coating / Cathodic protectionAPI 650 / OISD
DM WaterSS304Pickled & passivatedIS 2825
CondensateSS304 / MSEpoxy coating (MS)IS 2825
Chemicals (dosing)SS316 / PPN/A (material inherent)ASME Section VIII
Service WaterMSEpoxy coatingAPI 650 / IS 2825

Safety Features for Power Plant Storage Tanks

  • Secondary Containment (Bund Wall) – Concrete dike around tank to contain spills (as per OISD/EPA norms).
  • Overfill Protection – High-level alarms and automatic shutoff systems.
  • Pressure/Vacuum Relief – Conservation vents for atmospheric tanks.
  • Flame Arrestors – For flammable liquid storage.
  • Grounding & Bonding – Static dissipation systems.
  • Leak Detection – For double-wall tanks or interstitial monitoring.
  • Fire Protection – Foam systems, water spray, or fire monitors as required.

Heating Systems for Fuel Oil Tanks

For Heavy Fuel Oil (HFO) storage, heating is essential to maintain pumpable viscosity. We offer:

  • Steam Heating Coils – Internal coils with steam tracing for even heating.
  • Electric Immersion Heaters – For smaller tanks or where steam is not available.
  • External Heat Tracing – For tank outlets and piping.
  • Insulation – Mineral wool or PUF insulation with aluminum cladding.
  • Temperature Control – RTD/thermocouple with PLC control.

Technical Specifications

  • Capacity: 1,000 liters to 10,000,000+ liters (field fabricated)
  • Material: Mild Steel (MS), SS304, SS316
  • Design Standards: API 650, API 620, IS 2825, ASME Section VIII, OISD
  • Pressure Rating: Atmospheric to 10 bar
  • Temperature Range: -20°C to +200°C (with heating)
  • Wall Thickness: 6mm to 30mm depending on capacity
  • Bottom Type: Cone bottom, flat bottom, dished bottom
  • Fittings: Manhole, inlet/outlet nozzles, drain valve, vent, level indicator, thermometer, sample valve
  • Testing: Hydrostatic test (1.5x design pressure), vacuum test, weld radiography (as required)

Design & Manufacturing Standards

  • API 650 / API 620 – For large atmospheric storage tanks
  • IS 2825 – Indian standard for unfired pressure vessels
  • ASME Section VIII Division 1 – For pressure vessels (U-Stamp available)
  • OISD (Oil Industry Safety Directorate) – For fuel oil storage
  • EPA / CPCB – Environmental compliance for spill containment

Quality Assurance & Testing

Every storage tank manufactured by Shivam Engineering & Fabrication undergoes:

  • Hydrostatic pressure test (1.5x design pressure)
  • Vacuum test (for atmospheric tanks)
  • Radiographic inspection of critical welds (as per code)
  • Dye penetrant or magnetic particle inspection
  • Dimensional inspection as per certified drawings
  • Material certification (Mill Test Certificate)
  • Coating thickness verification (for epoxy-coated models)
  • Heating coil pressure test (for fuel oil tanks)

Serving Power Plants Across India

Shivam Engineering & Fabrication supplies storage tanks to thermal power plants, captive power plants, and industrial boilers in:

  • Maharashtra: Mumbai, Pune, Nashik, Nagpur, Chandrapur, Koradi, Paras, Bhusawal
  • Gujarat: Ahmedabad, Vadodara, Surat, Rajkot, Jamnagar, Mundra
  • Madhya Pradesh: Satna, Singrauli, Bina, Khandwa
  • Chhattisgarh: Korba, Raipur, Raigarh
  • Odisha: Angul, Talcher, Jharsuguda
  • Telangana: Ramagundam, Kothagudem
  • West Bengal: Durgapur, Kolaghat, Farakka
  • Tamil Nadu: Chennai, Tuticorin, Neyveli
  • Andhra Pradesh: Vijayawada, Visakhapatnam, Krishnapatnam
  • Uttar Pradesh: Singrauli, Anpara, Dadri
  • Rajasthan: Kota, Chhabra, Suratgarh
  • Karnataka: Raichur, Bellary, Kudgi

Frequently Asked Questions – Storage Tank for Power Plants & Boilers

1. What type of tank is used for heavy fuel oil (HFO) storage in power plants?

HFO storage typically uses large vertical cylindrical tanks (API 650) with cone roofs, steam heating coils, insulation, and secondary containment bunds. Capacities range from 500 m³ to 10,000+ m³ depending on plant size.

2. What material is best for DM water storage tanks?

For DM water storage, SS304 is standard. The internal surface should be pickled and passivated to maintain water purity. Nitrogen blanketing is recommended to prevent CO2 absorption and maintain resistivity.

3. Do you provide tanks for FGD (Flue Gas Desulfurization) additives?

Yes. We manufacture limestone slurry storage tanks and ammonia/urea storage tanks for FGD and SCR systems. These tanks are typically SS304 or rubber-lined MS depending on the chemical service.

4. What is the typical delivery time for a power plant storage tank?

Small tanks (up to 50,000 liters): 20-25 days. Large tanks (50,000-500,000 liters): 30-45 days. Very large field-erected tanks: 60-90 days depending on capacity and site conditions.

5. How can I get a quote for a storage tank for my power plant or boiler?

Call Mr. Nitin Panchal at +91-90168 77642 or email shivamenggfabricators@gmail.com. Provide required capacity, liquid to be stored, temperature requirements, and design code preference – we'll respond within 24 hours.

Get Your Storage Tank from a Trusted Manufacturer

As one of the leading storage tank manufacturers for power plants and industrial boilers, Shivam Engineering & Fabrication provides:

  • Free technical consultation and tank sizing assistance
  • Heavy-duty MS, SS304, and SS316 construction
  • API 650, IS 2825, and ASME code compliance
  • Fuel oil tanks with heating coils and insulation
  • DM water tanks with pickled and passivated finish
  • Chemical dosing tanks with agitators
  • Secondary containment and safety systems
  • Field fabrication for very large capacity tanks
  • Hydrostatic testing and third-party inspection
  • Material certifications (MTC) with every tank
  • Pan-India delivery and on-site installation

Contact Mr. Nitin Panchal at +91-90168 77642 or email shivamenggfabricators@gmail.com. Let Shivam Engineering & Fabrication engineer the perfect storage tank for your power plant or industrial boiler.

* All specifications and performance data are based on standard operating conditions. Custom requirements are engineered per client process parameters.